diplomat adp8322

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #23549
    sandysuds
    Participant

    Hi guy,s can anyone help machine switches straight on to the 1st light ,bleep,s constantly.and flashes,no set flash sequence, drains for a min then stops, but continues to bleep and flash.

    Can i wish everyone a merry christmas and new year.

    #198513
    Penguin45
    Participant

    Re: diplomat adp8322

    Whirlpool in a skirt – sounds like the classic NTC failure.

    Chris.

    #198514
    sandysuds
    Participant

    Re: diplomat adp8322

    thank,s Chris, you were spot on

    #198515
    keithwilliams
    Participant

    Re: diplomat adp8322

    had decided these symptoms were ntc fault the other day. this thread confirmed my suspicions and i’d like to say it was correct.
    thanks for the advice.
    p.s. curiously the multimeter read both the good and faulty one to virtually the same value.

    #198516
    Penguin45
    Participant

    Re: diplomat adp8322

    keithwilliams wrote:curiously the multimeter read both the good and faulty one to virtually the same value.

    Funny, isn’t it? I’ve fitted quite a few of these; all the ones removed gave a reading in kOhms. Haven’t had a “dead” one yet.

    Chris.

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.