  • #24042
    cornflakes
    Participant

    just visted this appliance

    Main oven element took out 30amp mcb..element shot it

    no probs I thinks! but

    fan starts up upon intitial switch on of control thermostat..after a couple of minutes it stops dead

    temp light remains on..but no rotation. what ever you do with control knob..fan will not start

    so before I remove monster from housing

    any ideas why fan STOPS

    many thanks

    Graham

    #200326
    Martin
    Participant

    Re: creda europa N230EW

    cornflakes wrote:any ideas why fan STOPS

    Two theories spring to mind here:

    1) The fan motor is knackered (thats why the element overheated and blew?)

    2) When the element blew it fused the t/stat contacts or the selector switch contacts?

    #200327
    bzz67
    Participant

    Re: creda europa N230EW

    does the motor still hum as if there is still power getting to it!

    #200328
    Martin
    Participant

    Re: creda europa N230EW

    cornflakes wrote:so before I remove monster from housing

    Yep! that’s the only sure way to find out for sure what’s wrong….drag it out! 😉

    What you need is one of these….

    I can see a potential marketplace opening up for my unique product? 💡

    #200329
    bzz67
    Participant

    Re: creda europa N230EW

    my dual height workmate does the job just fine.

    #200330
    tanner
    Participant

    Re: creda europa N230EW

    I have got a b&d workmate 5 years of hard abuse and it is still the biz 😆

    #200331
    cornflakes
    Participant

    Re: creda europa N230EW

    guys used all sorts to lift units out..but must say workmate is fine
    although if you aint got it in the van,, a plastic garden table ( strong one) or those nice ornatemetal ones. or like last friday a strong linnen basket upside down

    returning to the story

    fan runs upon turning regulator on..no undue noises from fan present

    so you suspect just the element..until after a few mins..fan stops

    I am beginning think that by taking out the 30amp mcb, stat may have shot it

    although heat call light stays on when fan stops!! so thats puzzling

    so i am armed with fan and element and if some kind person can give me stat part number it would be appreciated and we cant fail (says he)

    Thanks for swift responses..are you all still on christmas holidays

    graham

    #200332
    cornflakes
    Participant

    Re: creda europa N230EW

    job done..

    it pays to switch on the kitchen lights

    DOOR SWITCH!!!!! TOOK THE OVERLOAD