    I’ve got to go to of of these machines with an “FA” fault code. Can anyone tell me what is the usual cause of this?

    Cheers,
    Dave

    #202853
    Penguin45
    Participant

    Re: Diplomat D/W ADP8332

    FA. 11 Flashes. OWI failure. Dirty OWI lens. OWI defect or control board defect. Check cabling.

    From Error Cose thread.

    Chris.

    #202854
    eastlmark
    Moderator

    Re: Diplomat D/W ADP8332

    the wi being the black diaphram thing in the sump. Often just covered in crud but do fail now and then.