Hi my GW709AU had a replacement rebuilt main board put in about 3 years ago after the first year the machine was dead, i found one of the fuses blown, strangly it was a 1.6A micro fuse however the board says 2A, i guess the board repairer ran out of 2A fuses. Anyway to stay on the safe side i replaced it with a 1.6A and all was working fine although every blue moon i needed to replace that 1.6A fuse. Now its dead again same problem but this time fuse blows as soon as power is switched i even tested a 2A fuse, then tested power to the board with nothing else plugged in and again blows the fuse.
I Have made the following resistance tests:
1. Drain pump – 32.6 Ohms
2. Hot Water Valve – 61.5 Ohms
3. Cold Water Valve 62.7 Ohms
4. Wash motor 32.3 Ohms between phases & 16.1 Ohms per winding
5. Thermistor 10.24k Ohms
I noticed a slight chip on one of the transistors so i guess that could be damaged can’t make out the value. I will be replacing the board tomorrow as well as replacing the rotor sensor as advised by the spare shop, if anyone could offer any further assistance i would greatly appreciate it.