Htpt DWF40 help.

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #24783
    effzedarr
    Participant

    Htpt DWF 40 s/n 26700800,customer complained that m/c stopped & wash & dry lites flashing, this indicated Heater ,relay ,connection or module. Checked heater ,wiring ,connections, the relay seems to be part of the pcb. So fit new pcb pt# C00143206, m/c heats up [great thought me], now after about an hour m/c stops & you guess right , lites as before flashing ,yet the m/c is still warm/hot when you open the door .Wiring checks thro’ to the heater, disp solenoid ,float sw etc :rolls: so is it a faulty pcb or are the built in stats/cut-outs in the heater breaking down? It heats up to temp ok, this is doing me head in !!! 👿 👿 Any help guys is much welcome!
    regards Chris..

    #203293
    gazza57
    Participant

    Re: Htpt DWF40 help.

    heaters are very prone to have a earth fault and this can lead to problem you give.
    megger may not show earth fault.
    also worth checking customers socket for polarity and earth.
    regards gazza

    #203294
    effzedarr
    Participant

    Re: Htpt DWF40 help.

    Cheers Gazza ,I will look into it, ordred new pcb just in case, not that I’m questioning Merloni’s quality control :rolls: .
    regards Chris..

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.