hoover tumble dryer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #24800
    abbots
    Participant

    HVR HNC160-80 31100067


    machine dead except for “on ” neon.

    before i order a new timer for this can any one tell me were the pressure switch/microswitch is situated and how difficult it is to replace.it should indicate “cassette full” when operated
    it probable does the same job as the float microswitch on the hotpoint/creda condensor dryers.
    has anyone got a part number for it?
    thanks.
    jk

    #203363
    Martin
    Participant

    Re: hoover tumble dryer

    abbots wrote:can any one tell me were the pressure switch/microswitch is situated and how difficult it is to replace.

    It just has a Float Microswitch situated behind the condenser. Front panel off and drum out to access, clean and refit. 😉

    Try to stick to one thread if you would please, thanks 🙂

    #203364
    abbots
    Participant

    Re: hoover tumble dryer

    thanks martin.

Viewing 3 posts - 1 through 3 (of 3 total)