Bendix BWD1012 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Bendix BWD1012 This topic has 2 replies, 3 voices, and was last updated 19 years, 1 month ago by brett1611. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts February 13, 2007 at 12:04 pm #25012 brett1611Participant Hi — this appliance starts on most progs for a while then the timer just clicks onto the stop point. I had it just about to ramp up into a spin but then it clicked on and stopped. I’m thinking timer as all else seems ok.. ANY IDEAS ?? Ta Brett February 13, 2007 at 5:55 pm #204231 cabParticipant Re: Bendix BWD1012 hi was it trying to go into spin on wash? try the tacho loose in motor quite common on these. cab February 17, 2007 at 1:24 pm #204232 comptonappliancesParticipant Re: Bendix BWD1012 cab wrote:hi was it trying to go into spin on wash? try the tacho loose in motor quite common on these. cab can be 2 things no tacho signal or short circuit/open circuit ntc Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In