Bosch WTA3200GB/09

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #25080
    S1MON
    Participant

    Went to look at one of these today customer says it is not drying properly and aborting the cycle. For example it was on sensor dry and ended after only ten minutes of tumbling

    Checked element and stat all ok, lots of life left in the carbon sensor. Venting fine and fan is ok.

    What else should i be looking for on this

    Thanks

    #204428
    scots
    Participant

    Re: Bosch WTA3200GB/09

    Hi Simon

    I have been working on a prob with one of these machines, does your machine heat in both directions?

    Does your dryer have a manual time setting to see if the prob is to do with the sensing for dryness.

    I am sure youve thought of this but just in case, make sure there is a damp load in the dryer when checking.

    #204429
    Kentish
    Participant

    Re: Bosch WTA3200GB/09

    No moisture ingress into the heater wiring plug shorting out the heater probe?

    #204430
    S1MON
    Participant

    Re: Bosch WTA3200GB/09

    Went back today set it on manual and it heats but only sightly. Tried it again on setting one and it did the same.

    I replaced the board and duct sensor and left on setting one for 15 minutes and it appears to have done the trick. WAs getting nice and hot,

    Going back friday with a new plinth so we find out for definate then.

    Bit odd thou as everything belled out fine and the relay did switch on the old broad….

    #204431
    Penguin45
    Participant

    Re: Bosch WTA3200GB/09

    S1MON wrote:the relay did switch on the old broad….

    😯
    You’ve got some really strange customers, Simon……..

    Chris.

    #204432
    S1MON
    Participant

    Re: Bosch WTA3200GB/09

    😀

    #204433
    gegsy
    Participant

    Re: Bosch WTA3200GB/09

    S1MON wrote:……….the relay did switch on the old broad….

    😆

    Greg

Viewing 7 posts - 1 through 7 (of 7 total)