Diplomat ADP 8324

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #25115
    S1MON
    Participant

    This thing is a bit of a pain in the backside

    Original fault E2, cleared hoses and sump etc all sorted for a couple of weeks. Then comes back with no heat and dispenser not opening and not drying.

    Belled out heater and stat ok, solenoid on dispenser o/c and ntc needed replacing. All fitted and worked a treat.

    Now its still not drying properly, sometimes the dispenser opens sometimes not (seems to catch on top basket???????) and starting flashing E2 even thou the hose is clear

    Checked he bord all appears ok, run it throu a cycle and heater fine.

    Any ideas

    #204542
    eastlmark
    Moderator

    Re: Diplomat ADP 8324

    dipsenser is supposed to catch on top basket, it will still open enough to let soap out. If you get contuinual E2’s then changing the air break is usually the only solution. 766610112

    #204543
    S1MON
    Participant

    Re: Diplomat ADP 8324

    ok cheers will have a look at that.

Viewing 3 posts - 1 through 3 (of 3 total)