Called to above yesterday customer saying set m/c and filled and washed then stopped after approx 40 mins and led 4 lit. When i set m/c same happened but led 3 lit. The dispenser did not open and i checked voltage to heater @ 0 volts, when i removed tags from heater i had 240v and 30 ohms resistance across heater , when replaced tags 0v. Pressure system ok. Any ideas where to go nxt possible pcb? cheers Paul.
The saga continues I fitted a heater to this m/c and the same fault is present, although the dispenser fault is resolved ( customer forced shut after inserting tablet) Do i order PCB ,.
hi, if you try to start a prog with the heater disconnected it should go straight into a fault mode sensing that the heater is OC, if it does not then this will prove a fault on the module,