  • #25921
    Penguin45
    Participant

    This is an odd one…… Ivan down in Poole (not into computers) is getting the F6 fault – I’ve walked him through the flow meter problem, and he says he’s getting output from it. He has now changes the board. The machine will run in 2.5 minute bursts, before doing F6. If he opens and closes the door, it will do another 2.5 minutes, ad infinitum.

    I have a horrible suspicion that this is going to turn up in my workshop next week, so any advice would be appreciated.

    Thanks,
    Chris.

    #208115
    EFS
    Participant

    Re: Wpl ADP7966

    The fault described doesn’t sound like a component failure.
    Restricted water inlet or drain syphoning could be the cause.
    I had one this week showing a variety of fault codes and it turned out that the customer hadn’t cleaned the gauze filter from new which was upsetting the water indicator switch.
    Best to look for the low tech solution first before opening the tool box is my motto.
    Difficult to do on the phone though.

    Steve

    After thought.
    Poxy askoll wash pump can throw up strange faults.

    Good luck