Indesit WD10 Query

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #26605
    arosview
    Participant

    Hi All,
    I have a pain called a WD10, All the usual, abort timer, 10 flashes, programme not resetting, pump and dryer motor starting etc, etc. I found a thread posted 2004, which suggests that the answer is a new press switch + PCB + EEPROM.

    Could anyone tell me if this is still the current thinking or have things moved on since?

    Cheers David

    #210783
    hotpnt
    Participant

    Re: Indesit WD10 Query

    hi, F10 is pressure switch not sensing correctly, this is the module is not recieving the level settings it expects, worth checking the pump & valves are all ok first, if all fine start with the pressure switch, (may be stuck) if still same then unfortunatly it will be board & eeprom too, hope this helps

    #210784
    Penguin45
    Participant

    Re: Indesit WD10 Query

    P/sw can carbonise internally, so clicking or not, it can still allow current to flow when you don’t want it to.

    Penguin45.

    #210785
    arosview
    Participant

    Re: Indesit WD10 Query

    Cheers Guys,
    Pressure switch first then, and hope it’s not the board. The only good thing about throwing every part at it, is the first time completion rate soars!!
    I’m lucky this is a holiday home and I have 2 months to sort it.

    David

Viewing 4 posts - 1 through 4 (of 4 total)