Whirlpool Technical.

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #27061
    happycack
    Participant

    Anyone out there experienced with the Whirlpool commercial range, specifically the 3RAWZ tumble dryer. I think I need a Whirlpool engineer but maybe someone is familiar with it.
    Problem is it’s totally dead. Checked power, thermal cut-off, hi-limit stat etc but no joy. Any common faults or hidden internal fuses or even phone number to technical department of Whirlpool will do; all I get is ‘sorry Sir, can’t help you there’.
    Thanks.

    #212466
    johnmac11
    Participant

    Re: Whirlpool Technical.

    If it is an AWZ481 take the top off and go to the l/h side looking from the front, there is a fuse in the harness below the metal plate.


    John

    #212467
    happycack
    Participant

    Re: Whirlpool Technical.

    3RAWZ481E to be precise. It sounds good to me as it does have a metal plate covering the loom on the l/h/s/. I’ll check that tomorrow but it shows no internal fuse on the wiring diagram so I didn’t look too closely. I know the older models did. Thanks John for getting back, hope you’re right. Can I abstract the urine and ask if you know what current rating it is as its miles away and nowhere to buy fuses locally.
    Ta. Paul.

    #212468
    johnmac11
    Participant

    Re: Whirlpool Technical.

    happycack wrote:3RAWZ481E to be precise.

    The full number wont go into SIOS, if you are looking for this model miss out the “3R” part.

    Fuse is a 8A 20mm glass fuse.


    John

    #212469
    happycack
    Participant

    Re: Whirlpool Technical.

    Got some of them, thanks again John, will let you know outcome when I’ve been back.
    Paul.

    #212470
    happycack
    Participant

    Re: Whirlpool Technical.

    Spot on John. Might have stumbled on a new nick-name for you!
    Thanks again.
    Paul.