Bosch KGV3104 erratic

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #27444
    don
    Moderator

    Bosch KGV3104gb/04. Problem being fridge and freezer will only cut in and out when stat is set at 4 or over which is making machine too cold. If set lower, machine not getting cold and compressor gets raging hot.Suspect control PCB, where is the thermal probe as one of our guys can`t trace it?

    Thanks

    Don

    #214061
    gegsy
    Participant

    Re: Bosch KGV3104 erratic

    Hi Don
    Fridge NTC is behind a cover in fridge compartment 8) , evaporater sensor is foamed in and cannot be replaced (this is the sensor bypassed via the “well documented” modification)

    Regards
    Greg

    #214062
    don
    Moderator

    Re: Bosch KGV3104 erratic

    Hi Greg

    Thanks for the info. Recieved email pdf, will pass info on to engineer.