    Hi guys
    after about two minutes of washng all the prog lights flash and it beeps ,I asssume it’s a fault code but what it is I don’t know .
    does anyone have a procedure to interrogate the machine on a PDF ?
    Here’s hoping
    Lawrence
    if you have – L.carey4@NTLworld.com

    #214846
    Seamy
    Participant

    Re: Miele G1180vI

    G1180 will try to start circulation motor 10 times after it fills with water & if pressure is not sensed it will abort programme.
    I presume this is whats happening.
    You will need to check circulation motor to see if its seized up.
    Remove base of machine, 2screws at front under plinth & 2 screws on base near back , remove bracket screw on lower back panel mounting motor. Remove hoses & unclip pressure switch & wiring. Motor should ease out. Take heater plate off pump & you should then see if theres an obstruction fouling the impellor.
    Sometimes these seize up if they haven’t been used for a while & you may find that it just needs a sharp turn to release.