Indesit WD12 13 flashes

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #27757
    Simon46
    Participant

    Is this usually a broken wire or dryer thermistor itself? What is reading at room temp?Faults a minute into wash.

    Regards
    Simon

    #215494
    DAR01
    Participant

    Re: Indesit WD12 13 flashes

    Last one i had like that was wire broken on one of the stats, check wiring to dryer heating element.

    Mike

    #215495
    helo_75
    Participant

    f13 is deffo a dryer fault, and its usually the thermal fuse or the thermistor on the heater box has broken

    #215496
    Simon46
    Participant

    Re: Indesit WD12 13 flashes

    Ta guys NTC O/C. Took it apart tarnished internal spring conns. cleaned all ok.

    S.