Hotpoint WD71

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #28100
    don
    Moderator

    Can anyone please help out a desperate engineer we have here?

    Got a customer with a WD71 with no tumble dryer heat. Upon investigation it has now power to element, he has checked the TOC, thermostat, element and wiring loom for breaks everything appears to be okay. The power board had been replaced a little ago due to a physical break after machine went AWOL on a spin cycle but dryer has worked okay since.

    Any ideas anyone ❓

    Thanks

    Don

    #216896
    Martin
    Participant

    Re: Hotpoint WD71

    don wrote:Any ideas anyone ❓

    Well now on the assumption that the programme module accepts the command and no error codes ensue? And that the blower fan burst into life together with the inlet valve? Then with no power to the elements/toc’s and no obvious breaks in wires it simply has got to be the POWER MODULE (relay probs I expect?) 😕

    #216897
    don
    Moderator

    Re: Hotpoint WD71

    Thanks Martin :tup:

    I`ll pass the info onto the engineer.

    Don

    #216898
    iadom
    Moderator

    Re: Hotpoint WD71

    Sent you an e-mail Don, it might come in handy.

    Jim.

    #216899
    don
    Moderator

    Re: Hotpoint WD71

    iadom wrote:Sent you an e-mail Don, it might come in handy.

    Jim.


    Thanks Jim very much appreciated. Just attached it to the engineers job sheet.

    Don

Viewing 5 posts - 1 through 5 (of 5 total)