the cooling fan is not working.
the fan motor is fine, but no supply to it.
connect list’s a “cut in” stat, but i cant find one on the machine.
i presume that the phase is picked up from the output of the trigger board, do these fail very often?
if so has any one a part number?
and also i will change regulator for the grill at the same time, any one a part number for it.
thanks.
john
From memory on most Creda cookers & ovens theres a stat mounted on the top behind the controls its normally open contact, its a low temp’ cut in at approx 40-50C & runs cooling fan until temp is returned to below setpoint even after switch (for grill/top oven etc) is off.
After dc 96 Novemeber 2001 Trigger board was removed and cut in stat was used, you have a dc 74 so you will require 6222118 Trigger board it is situated above mains terminal block.