Indesit WIL103 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Indesit WIL103 This topic has 2 replies, 2 voices, and was last updated 18 years, 9 months ago by pmb. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts July 7, 2007 at 8:15 am #28799 pmbParticipant Easy iron and extra rinse lights flashing, Is it prssure chamber ? The machine is in a mobile home, They had a great idea of changing the kitcen so there is only minimum space between worktops So i only wont to get this machine out once July 7, 2007 at 12:35 pm #220156 deltraParticipant Re: Indesit WIL103 hi pmb, if light 2 is on its fault code F04 press sw stuck on empty iflights 2&4 fault FO5 press sw stuck on full, hope that helps ❓ July 7, 2007 at 12:37 pm #220157 deltraParticipant Re: Indesit WIL103 and lights 1&3 F10, press sw not sensing Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In