    Hi,

    I fitted a new belt (Pt No C00074218) to this machine 2 months ago
    because the old one slips off sometimes when in use.

    The customer says it has happened again.

    I remember when fitting the belt that it seemed to go on very easily
    rather than the very tight fit this type of belt usually is – I`m assuming it
    is a `stretch` type.

    Is there another that fits that is smaller than the 1046MM 8H belt.

    Thanks

    Laurence

    #220481
    iadom
    Moderator

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    Thats the only one shown, not unknown for the wrong part to be in the bag, everyone I have had has been a tight refit.

    Jim.

    #220482
    laurenceuk
    Participant

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    Thanks again Jim.

    Laurence

    #220483
    iadom
    Moderator

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    Just checked on a new, gen one I have, on the belt it says 1051 H8 MAEL.

    On the packaging it does say…. Belt = 1046 – 1051H8 MAEL.

    Jim.

    #220484
    Seamy
    Participant

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    5mm larger then?

    #220485
    FSE-style
    Participant

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    find out if its ever had a new tank fitted!

    chances are if it had, it could have one of the 6 different types of pulleys!

    cheers

    #220486
    laurenceuk
    Participant

    Re: Ind W161UK Wash M/c – New Belt Seems To Big

    Thanks for your responses.

    I went to fit a new belt today and though it is exactly the same as the
    belt I fitted earlier as per Partfinder, this one was much harder to pull
    over the pulley than the previous one.

    I wonder if the first belt I fitted had been taken off returned machines or
    those that had failed testing then put back in stock – by Indesit Company
    I mean 😕

    Thanks again