F&P Error 50 after new Hot Valve

Home Forums Public Support Forums International Forums Australasian Appliance Forum F&P Error 50 after new Hot Valve

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #28930
    Pattym
    Participant

    Hi

    I have a Fisher & Paykel GW609NZ. When you switch it on and start a cycle it runs for 2 seconds, stops, and runs for 2 seconds again. After about 30 seconds it starts beeping and shows error 50 (00011010). So I bought a new set of cold and hot valves from F&P and installed them. This made no difference.

    The error codes as displayed in the diagnostic menu are

    0000 – 0000 0000
    0001 – 0000 0101 / 0000 0110
    0010 – 0000 0001 / 0000 0000
    0011 – 0011 0010
    0100 – 0000 0010
    0101 – 1011 1011
    0110 – 0000 0111
    0111 – 0000 0001
    1000 – 0000 1101
    1001 – 1011 1011
    1010 – 0000 0111
    1011 – 1111 1111
    1100 – 0000 0101 / 0000 0110
    1101 – 0001 0001
    1110 – 0001 1011
    1111 – 0010 1010

    I have been scouring the internet for nearly a week now and most other people with an error 50 solved their problem with the replacement of the valve.
    One more thing, as the valves are labeled as 24V i thought I’d check to see what the voltage coming out of the control board was, and I measured a max of 12V, but usually hovering around 8V.

    #220706
    Penguin45
    Participant

    Re: F&P Error 50 after new Hot Valve

    New valve unlikely to be faulty. Common problem is the wiring itself – check harness from Controller to valves for continuity, check for oxidisation at board end. Failing that, it’ll be a supply problem from the board itself.

    Regards,
    Penguin45.

    #220707
    Pattym
    Participant

    Re: F&P Error 50 after new Hot Valve

    It wasn’t the wiring. I checked the resistance in the valves, unsoldered the cables checked the resistance through the cables, resoldered and checked again. Every time getting 66Ohms, so it must be the board. I guess I’ll have to shell out $165 for a new board.

    Thanks for your prompt reply Penguin45

    #220708
    crew
    Participant

    Re: F&P Error 50 after new Hot Valve

    I have the same problem but with a different model.

    Model: mw059au Fisher and Paykel Smart Drive 5.5
    Error code: 50 // 00110010

    I have tested the resistance on the valves 63.5 (cold) and 63.7 (hot). The power supplied to the cold valve when running seems to jump around from 0V to 7ishV, whilst the cold seems to sit at 7V to 8V.

    I assume a faulty board, but was hoping for more information on the error and what components tend to fail. I would rather a $0.20 component to a $165 board that may or may not work.

    Thanks.

    #220709
    crew
    Participant

    Re: F&P Error 50 after new Hot Valve

    I just saw this page, it might help you too 🙂