GW701 Error code 43

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #29250
    fcollingwood
    Participant

    Just when I thought I’d got the damn thing licked…..

    Can anyone tell me what 00101011 (43) means?

    #222482
    bigsmokepiker
    Moderator

    Re: GW701 Error code 43

    Out Of balance switch fault
    Check OOB microswitch (Terminals corrode) Also Check Switch housing pins that hold in OOB Switch Break (Plastic)

    Switch located in top console RHS under Motor Controler(PCB)

    #222483
    Jazz
    Participant

    Re: GW701 Error code 43

    hey there,

    Just had the same prob. tried to fix the switch, didnt work. If you want an easy fix just connect the yellow and white wires coming of a 4 pin connector on the right hand side just under the control panel that go to the switch. The machine wont shut off if it gets out of balance but it will work.

    Cheers

    Jazz

    #222484
    Penguin45
    Participant

    Re: GW701 Error code 43

    Safety device – must be replaced at the earliest opportunity.

    Penguin45.

Viewing 4 posts - 1 through 4 (of 4 total)