    Bernie
    Participant

    Hotpoint Dishwashers solenoid valve safety device activating. This happens maybe once or twice a month at the most.
    All I do is turn off the water, remove inlet hose switch machine on switch it off again, connect hose turn water back on.
    Have fitted a new solenoid but it still does it any suggestions please.
    This is on my own machine.

    Bernie

    #224045
    johnnyj
    Participant

    Re: Hotpoint Dishwasher BF31

    Check the sump hose between metering tank and sump if it is gunged up it will, cause the safety shut off to activate.

    #224046
    bubs
    Participant

    Re: Hotpoint Dishwasher BF31

    If it’s got a plastic sump hose; Fit the replacement rubber one. Also clean the comb pump filter in sump as i find slow draining can also cause this.
    Cheers Graeme

    #224047
    johnnyj
    Participant

    Re: Hotpoint Dishwasher BF31

    The rubber ones can get gunged up as well over a period of time.

    #224048
    Bernie
    Participant

    Re: Hotpoint Dishwasher BF31

    Thanks for the suggestion will give them a look.


    Bernie