    freddieboy
    Participant

    hi ,i am wondering if any one can give me any advice.i have a zanussi jetsystem timeline 1600,which work great till last week.when it stopped taking in water ,after checking the filters on the inlet hose and the pump as well as a general gander inside to see nothing had come loose.decided that the inlet valve solenoid had gone so i ordered the part and three days later it arrived.i replaced the part and yes nothing happened looking back. i think i jumped the gun the next day i tried it again and i worked for a couple of washes and then it stopped before the rinse came on it then came up with the error code e30.we have tried it a couple of times and if it works it will only wash then doesnt rinse or spin and no error codes come up has anyone any ideas i have read through the forums and cannot even find my model mentioned.thanks for reading this 😯

    #224055
    helo_75
    Participant

    e30 would point to an incongruency betyween the analogic pressure switch and the antiboil switch

    of course it could be a chaffed pressure tube, thats common

    in laymans terms, it isnt sensing the water level

    id check both pressure hoses/pressure bottle

    deffo plug out b4 inspecting