beko 1715

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #30038
    Owain84
    Participant

    Machine won’t start at all – Prewash light flashing

    Run test program, everything works except fill to check leaks.


    Ne ideas?

    #225627
    Owain84
    Participant

    Re: beko 1715

    when i say prewash i dont mean button perwash indicating child lock i mean the prewash light on the right hand side

    #225628
    kwatt
    Keymaster

    Re: beko 1715

    Fault codes as follows:

      H1 : NTC OPEN CIRCUIT OR SHORT CIRCUIT ( 10000 )
      H2 : HEATER OPEN CIRCUIT ( 01000 )
      H3 : HEATER ALWAYS ON ( 11000 )
      H4 : VALVE TRIAC SHORT CIRCUIT ( 00100 )
      H5 : PUMP OPEN CIRCUIT ( 10100 )
      H6 : MOTOR TRIAC SHORT CIRCUIT ( 01100 )
      H7 : PRESSURE SENSOR FAILURE ( 11100 )
      H11 : MOTOR / TACHO OPEN CIRCUIT ( 00110 )

    Where “1” is the LED on and “0” is the LED off.

    The test sequence is in the fault code guide.

    HTH

    K.

    #225629
    Owain84
    Participant

    Re: beko 1715

    tried the reset and now works fine.

    Prewash flashing is time out on pump which once i tried the reset and ran a drain program, i realised it was slow. Took off outlet and a button was blocking the flow.

    Cheers

    If the Prewash aux button (left hand side) flashes then its child lock if its the prewash (right hand side) flashing its time out on drain!

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.