  • #30290
    roly16
    Participant

    However long you set it for this machine runs for 59 seconds then shuts down with the remaining time still displayed. If you re-start it the same thing happens each time. It also does it on convection cooking. I can’t think it’s anything other than the pcb but would be grateful for any other suggestions.

    Thanks.
    Geoff

    #226653
    Penguin45
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    http://www.ukwhitegoods.co.uk/modules.p … 59+seconds

    Chris.

    #226654
    roly16
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    Thanks Chris,

    I think I might just check the damper motor.

    Geoff

    #226655
    robbo1973
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    did this sort problem and anybody got part no for damper motor as i have rang electrue and they cant find it.

    cheers chris.

    #226656
    SWERV
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    Hi, this is the part code from connect 31765G, special order though :cry, and yes it should sort it out, done quite a few now.
    Merv

    #226657
    roly16
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    robinsonrobbo wrote:did this sort problem and anybody got part no for damper motor as i have rang electrue and they cant find it.

    cheers chris.

    Yes it did.

    #226658
    robbo1973
    Participant

    Re: Sharp Combi Microwave R957[SL]M

    :tup: