smeg e2

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #30494
    petalpop
    Participant

    i have been to a smeg d/w mod dwi710e1
    2nd light flashing which is overfilling
    checked in fault code book (everyone should have one)
    which says poss blockage in pipe in sump
    have checked it and it is as clear as a bell
    so i presume it must be the fill matrix
    am i missing something if not does anyone know the part number please

    #227390
    keithwilliams
    Participant

    Re: smeg e2

    i can’t give you a specific answer, but try this.
    i own a smeg (against better judgement), it was giving all sorts of error messages which were not consistent. i spent hours on it until someone got me to check the soap box solenoid coil. hey presto it was open circuit. pinched one off a washer valve made it fit and all errors disappeared.
    other than that i haven’t a clue

Viewing 2 posts - 1 through 2 (of 2 total)