Servis M6030S

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #30673
    neptune
    Participant

    Went to this today . Customer says original fault was machine would spin but not pump out. She had obtained and fitted a new pump. If you start machine on a programm, it now pumps out and fills at the same time time. Pump is definately running at the time. On looking at the old pump, it tested open circuit. Pressure switch seems ok. suspect module but would like to be sure . Anyone experienced this please?

    #228019
    Penguin45
    Participant

    Re: Servis M6030S

    O/C pump triac on computer board – probably blown when the old pump failed.

    Chris.

    #228020
    neptune
    Participant

    Re: Servis M6030S

    Thanks for that Chris. Probably best to send the Board to EMW
    Neptune

Viewing 3 posts - 1 through 3 (of 3 total)