Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #31992
    Toni
    Participant

    Have one of these thats overfilling.
    The pressure tube is clean thats the 1st thing I checked.
    When you blow in to pressure switch you only get one click & it starts to drain, but still carries on filling.
    Could it be pressure switch ? or module ?
    Any help please ?

    Toni

    #233187
    iadom
    Moderator

    Re: Hotpoint WM72

    If you do blow into the switch you should do so very gently, you should hear one click and the fill should stop, blowing a little harder will bring in the overfill switch, this does not ‘click’ but energises the pump. It should be possible to test the operation of the switch with a simple circuit tester. I can send you the wiring diagram if that will help you identify the individual contacts.

    Jim.

    #233188
    suedehead1
    Participant

    Re: Hotpoint WM72

    these machine are bad for the pressure switch tube rubbing on the top edge of the tub where it is fixed to the tub clips with a small tie wrap.

    #233189
    Toni
    Participant

    Re: Hotpoint WM72

    Thanks for replys on this
    new pressure switch ordered

    Toni

Viewing 4 posts - 1 through 4 (of 4 total)