SMEG DWI612C

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #32009
    ELTEL
    Participant

    😕 Hi I have a customer with a SMEG d/w the last 2 lights were on all the machine did was make a noise it seems the pump wants to pulse but nothing else any ideas

    #233245
    senseib
    Participant

    Re: SMEG DWI612C

    Hi ELTEL,

    Try the “Known error codes” above in this forum, pretty sure the solution to your query is in there. 😉

    Brian.

    #233246
    eastlmark
    Moderator

    Re: SMEG DWI612C

    dispenser coil I would guess at.

    #233247
    keithwilliams
    Participant

    Re: SMEG DWI612C

    i’d agree with the dispenser coil. i spent ages on my smeg chasing a weird fault, not listed in the codes. sure enough, i nicked a fill solenoid coil and it cured it.

    #233248
    bzz67
    Participant

    Re: SMEG DWI612C

    small rubber non return flap in sump is probably stuck.quick clean off will cure it. hopefully!

    #233249
    eastlmark
    Moderator

    Re: SMEG DWI612C

    bzz67 wrote:small rubber non return flap in sump is probably stuck.quick clean off will cure it. hopefully!

    Way off the mark there bzz67. Smeg have not used that set up for years.

    #233250
    Lawrence
    Participant

    Re: SMEG DWI612C

    Its the disp coil,sadly it may have taken the PCB as well.
    Lawrence

Viewing 7 posts - 1 through 7 (of 7 total)