  • #32176
    craigieboy
    Participant

    Hi ,sorry first post hope everything as it should be ,but having problems with a siemens integrated coffee machine model tk68e570,it is showing error number 8 when first switched on ,says it is heating water then error message shows ,have manage to find out that possiblilities are blockages with brewing unit ,but have stripped and left unit switched off for 1 full day as advised,am getting no power to grinding unit think should be ,so my guess is one of the modules, but want to try and verify before order
    thanks

    #233951
    gegsy
    Participant

    Re: siemens integrated coffee machine

    Hi

    Error 8 relates to –
    1 Incorrect operation – the brewing unit was filled with too much
    preground coffee or with whole coffee beans via the ground
    coffee slot.
    2 Incorrect operation – cleaning tablet was inserted too early
    and blocked the brewing unit.
    3 Wrong coffee settings – too much, too finely ground coffee.
    4 Wrong grinding unit setting – grinding too coarse, amount too
    large.

    Greg

    PS – What is the full enr after the …570??

    #233952
    craigieboy
    Participant

    gb/04 Have stripped brewing unit,grinding motor where beans are is is empty and there is no sign of a cleaning tablet or filter coffee thanks away for reply, as thought might be on my own with such a specialized unit

    #233953
    craigieboy
    Participant

    Re: siemens integrated coffee machine

    Got fixed today new power module had jumper cable on connections ,another mod not listed