November 15, 2007 at 9:25 pm #32238
TELL
ParticipantHard to believe, but it heats on both temps, low and high (too approx 90 deg’s. empty) and cycles down to about 70deg’s, this is on the high setting. fans ok, filters clear, and condensor etc, clear. customer is putting clothes in, and not overloading for 90 mins +, and still not dry. Any ideas?, i’ve seen there is a different set of stats, to the ones i carry, and i dont know the temps on these ones. Could the cycle stat be weaker on temp’s?. therefore taking a long time to dry?. anybody had similar prob’s.
TELL..November 15, 2007 at 11:01 pm #234186helo_75
Participanthave to say, its usually the condenser
, have you physically checked it or has the customer just said they have?other than that, its gotta be the stat in the front duct.. cant be anything else
November 16, 2007 at 12:18 am #234187Penguin45
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
Yup, front stat is the one everybody forgets.
Chris.
November 16, 2007 at 3:40 pm #234188TELL
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
YUP, your right, forgot
will check.
TELL..December 5, 2007 at 10:29 pm #234189TELL
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
well i’m back. checked the front stat, its ok. shorted out wires to test. still the same. got one of these plug in adapters to test wattage of elements, both coming in when selected. 1/2 heat gives a reading of approx 1.4kw, full heat 2.6kw. stripped out ducting no blockages, good air flow. and the thing is still not drying the clothes, timer set in excess of 100mins. ps. the water pump is working ok aswell. changed rear stats, white spot new type.
any ideas. i’m beat.
TELL..December 6, 2007 at 8:28 am #234190Seamy
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
Are clothes properly spun when taken from washing machine & is the dryer being overloaded?
December 6, 2007 at 7:46 pm #234191TELL
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
thats ok, and not overloaded. the drum temp inside is very poor, especialy with the clothes in,(half the load i would normaly put in. i found the element cycles on/off quite quikly, thinking it must be air flow, but there is no blockages in the ducts, and the heater blower fan goes like the clappers, aswell as the condenser fan at the front.
TELL..December 6, 2007 at 7:49 pm #234192HotDog
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
Did you check for blockage from condensor box to pump
December 6, 2007 at 7:58 pm #234193TELL
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
had pump off and checked through to condenser housing, all clear. also checked to make sure pump works, filled rear resevoir, pumps away ok.
its a good one!!.
TELL..December 6, 2007 at 8:05 pm #234194kiddo66
ParticipantRe: been to H/point CTD00G con’d drier. Not Drying Clothes?.
Tell I would be checking wiring from float switch to see if that is cutting out,the other thing is timer is it cyling on the stat or cycling because the timer is knocking it off?
The other thing that springs to mind is has anyone else been at the appliance because i had an old creda doing the same thing and the recirculating fan had been fit the wrong way round. -