  • #32245
    goosegreen
    Participant

    I know this has been covered many times but I have fitted 2 x 1701583 stat kits in the last 2 days and they are failing after one load. The customer is desperate as he looks after his very sick wife and needs a dryer. Have double checked for blockages, replace front stat and ensured that its reversing correctly. The machine is in a outbuilding so I don,t think its the door being opened all the time while hot. I feel for the guy and would like to sort it for him, So any other suggestions much appreciated.

    Thanks

    goose

    #234212
    iadom
    Moderator

    Re: H/Pm Tdc Cond Dryer

    Model number? If it has electronic controls then relay failure on module will cause this. Check to see that the drying light goes out when doing short reverse tumble.

    Jim.

    #234213
    goosegreen
    Participant

    Re: H/Pm Tdc Cond Dryer

    Jim. Its not an Electronic model.


    Goose

    #234214
    SimonCD
    Participant

    Re: H/Pm Tdc Cond Dryer

    how about capacitor, heavy load, fan wont turn and stats trip

    #234215
    Martin
    Participant

    Re: H/Pm Tdc Cond Dryer

    Simon_ wrote:how about capacitor, heavy load, fan wont turn and stats trip

    I agree, its a 7mf capacitor in those, stick in an 8mf and it’ll be fine. 😉

    #234216
    goosegreen
    Participant

    Re: H/Pm Tdc Cond Dryer

    Called back today watched it do a full load no problem, Will call back tomorrow and fit a new cap. Thanks for the replies

    Goose

    #234217
    bobokines
    Participant

    Re: H/Pm Tdc Cond Dryer

    Be a bit careful using an 8 MFD capacitor. I had one a few weeks ago that I had previously fitted an 8mfd to and it then kept overheating the motor. I now only fit a 7 to these machines.

    There is a 7mfd pattern part available now fromConnect CAP244

    The motor current rises to the square of the increase in capacitance. ie if you fit an 8 instead of a 7 you are increasing the running current by over 30{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d}

    Bob

    #234218
    kiddo66
    Participant

    Re: H/Pm Tdc Cond Dryer

    One thing i have found with these is that if it has a 2.5kw element on it as they get older and IMO the motors tend to slow down a bit they have a tendency to blow stats i fit the 2.3kw heater to these and usually find it cures the fault.

    #234219
    Andill
    Participant

    Re: H/Pm Tdc Cond Dryer

    had the same problem with C dryer, found that if its a timer controled dryer, I found that sometimes the drum on reverse does no start rotating again, took me a while to find this out myself, if the drum does not start rotating again the heater stays on and causes the limiter to go out,
    leave the dryer going with washing in for about 30 mins, if it does this it is a known timer fault.
    Andy

    #234220
    goosegreen
    Participant

    Re: H/Pm Tdc Cond Dryer

    Called back today and wouldn’t you know it, Done 3 loads no problems,
    Must be my magic touch :lol:. I think Andill was right, Thats the only reason I can see that would cause the stats to would fail so quickly. Advised the customer that if they fail again I will price up a new timer..


    Again thanks for all the help.

    Goose