Re: Hygena ahy8101 wont fill
Programme sequence is typically: drain, then fill, then circulation.
If the drain pump is not cutting out after a minute or so, the flood protection may be operating. The protection system is in tray under the machine. If the circulation pump is cutting in without any water, the machine may think that it’s already full, in which case you are looking at a problem with the water level control side of things. Finally, the valve may have failed and be simply not allowing fill. The coil should read c.3.5kOhms when metered.
Power off, if investigating.
Penguin45.