    cornwell40
    Participant

    😕
    this one behaves the way the relay start dryers do. Cuts out after a short time of working. Pressing the start button just creates a buzz. Can’t see a relay and customer assures me that when she opens and shuts the door after it stops it will start again. Aha door switch I thought, the loud buzz when the button is pressed sort of confirmed it to me as it came from the door area.
    Then I found the price of the door switch on it 😯 , nearly £20 to us.
    On further perusal of suppliers part list I find relays and pcb with relays under this model 😕 .
    Have I missed something???

    TC

    #235876
    helo_75
    Participant

    later models have a bitron door lock, and the relays part of the lock

    #235877
    cornwell40
    Participant

    Re: Creda TVU1 cuts out

    Ta for that.

    TC