    ……firstly no blockages anywhere and both pumps appear to be working.
    However………the machine will empty when there is a light load, but with a heavy load the drain pump runs but no water drains!!

    If I then lift the tub up slightly it will drain, equally if I simulate a heavy load i.e push down on top of tub it won’t drain.

    It appears to be some kind of air lock maybe? ANY help would be great!
    Many thanks
    Andrew 😳

    #236106
    Penguin45
    Participant

    Re: HOOVER AA230 INTERMITTENT DRAIN

    Droopy sump hose – replace.

    Chris.

    #236107
    Seamy
    Participant

    Re: HOOVER AA230 INTERMITTENT DRAIN

    Had a similar problem with Hoover & it was a faulty pressure switch. Going into flood protection intermittently.

    #236108
    trotter
    Participant

    Re: HOOVER AA230 INTERMITTENT DRAIN

    Cheers guys…….goto look tommorow ….will report back!

    #236109
    DDSDDS
    Participant

    Re: HOOVER AA230 INTERMITTENT DRAIN

    GO for the dodgy sump hose had a few of those.

    #236110
    neilsukwg
    Participant

    Re: HOOVER AA230 INTERMITTENT DRAIN

    Had droopy sump hose on a couple of the older Hpt Wma’s as well