white knight

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #33003
    DDSDDS
    Participant

    hello fellah’s
    i have made a mistake.

    i have a white knight sensordry quite old and have managed to disconnect the wires from he reverse timer andhave no clue which way they go back on.
    i have no model number its all worn away to nothing so can someone please tell me they have a wiring diagram or a similar dryer and can tell me which way they go back on.

    #237082
    DDSDDS
    Participant

    Re: white knight

    Anyone?

    #237083
    abbots
    Participant

    Re: white knight

    i don’t know if this helps but if my memory serves me correct for the CL511

    reverse timer connection :

    8 orange to no. 1 on the main timer
    3 red to no. 3 on the main timer
    2 black/white to terminal block
    1 black/white to exhaust stat
    5 yellow to capacitor
    4 blue to timer Y

    hope this may help a little.
    john

    #237084
    DDSDDS
    Participant

    Re: white knight

    Sorry just got around to dragging that dryer out again and spotted your reply i have wired as you said and the only difference is that my red wire was actually brown but it seems to be working fine now.
    thanks muchly

    #237085
    abbots
    Participant

    Re: white knight

    no worries