Hotpoint ctd00 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint ctd00 This topic has 2 replies, 2 voices, and was last updated 18 years, 3 months ago by timjam. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 15, 2007 at 1:31 pm #33032 timjamParticipant Hi been to this today and it keeps tripping RCD, the element is very wet , does anyone know the cause of this ? Thanks Tim…… :rolls: December 15, 2007 at 2:34 pm #237188 helo_75Participant yep, its usually because the hole from the pump through the base to the condenser is blocked, stick a cable tie through it to unblock it or, its been moved recently quite often, if you dry the element off, itll work fine December 15, 2007 at 2:40 pm #237189 timjamParticipant Re: Hotpoint ctd00 nice one! thanks 😀 Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In