Bosch SGS43A42UK/01

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #33273
    rocker
    Participant

    later type with access from base..
    This machine fills ok starts programe runs for hours dosent finish cycle. appears to try to empty but refills the same time also no heat.
    I fitted a new lower mirco switch fill/empty in base, still the same.
    can anyone advise on fault please. John.

    #238079
    nomadPaul
    Participant

    When you say it fills ok , does the water actually stop entering the machine once it reaches its level ? I’d be looking at the flow rate meter ( impellor jug ) , as they can give some odd faults . If it continually fills/empties , thats where i’d aim for first .

    #238080
    rocker
    Participant

    Re: Bosch SGS43A42UK/01

    nomadpaul.
    when the machine starts ,it fills to correct level, runs program so it appears to have fault near end of cycle, could it still be impellor fault!!
    and is the impellor in side tank ? and can it be repaired/replaced never worked on this machine before. John

    #238081
    nomadPaul
    Participant

    Actually Rocker , i’ve got the wrong machine. this doesn’t have an impellor jug. Sorry .

    It may have a magnetic float switch for its levels though . When looking down at the sump , there might be a small cover in the 5 o’clock position . If this lifts off , you might find a small magnetic float under it. These can sometimes get gunged up with grease and crap , hindering the floats travel . Remove the float – REMEMBERING WHICH WAY IT SITS – clean out the float channel and refit . This could help .

    #238082
    rocker
    Participant

    Re: Bosch SGS43A42UK/01

    Paul , I will check this float unit out, and let you know if it works many thanks john