GW708K WILL NOT FILL

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #33298
    kiwiaviator
    Participant

    After its 5th trip across the Tasman Sea, my F&P 7.5kg Excellence has packed a wee sad when I fired it up.

    It will not start filling when the cycle is started. Diagnostics show that both hot and cold inlet valves are functional. In the hold+slowspin mode error code is 00000000 which I assume means no errors.
    In the medspin mode (guessing this is a switch diag mode) I am getting 01000001 in a ‘normal’ state. If I activate the out of balance switch I get 01010001. If I lift the lid I do not get a change of state ie.. it remains on 01000001.

    I am suspecting a lid switch but could any kind expert out there confirm this or enlighten me please.

    PS. all above readouts are left to right.

    #238192
    Penguin45
    Participant

    Re: GW708K WILL NOT FILL

    Does it do anything at all? If you select spin, does the pump run, drum start to turn?

    Penguin45.

    #238193
    kiwiaviator
    Participant

    Re: GW708K WILL NOT FILL

    After leaving it on at wall for a day, it actually started by rotating and filling etc.. then i lifted lid and put down again and it didnt work. Lid sensor is changing state so i’m suspecting the power control unit now.
    Any thoughts?

    Thanks
    Kev

    #238194
    bigsmokepiker
    Moderator

    Re: GW708K WILL NOT FILL

    More than likely Lid Switch fault ( magnetic reed switch)
    Switch located under Hob RHS
    Part # 426457 About $40.00 Aud

    #238195
    kiwiaviator
    Participant

    Re: GW708K WILL NOT FILL

    New lid switch fixed OK. Thanks.

Viewing 5 posts - 1 through 5 (of 5 total)