Hotpoint FDW60 heater failure

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint FDW60 heater failure

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #33320
    S1MON
    Participant

    Have one of these models at the minute that is causing me some problems. It was flashing heater failure fault code led 4 and 6.

    The open circuit heater was repalced but the fault code is still coming up, I then changed the module but still it presists. I have checked all the connectors and the loom all appears ok.

    any ideas? Duff heater?

    #238278
    JOHN CLARKE
    Participant

    Re: Hotpoint FDW60 heater failure

    Draft idea I know but is the new heater unit OK.

    #238279
    S1MON
    Participant

    Well it tested ok on my meggar so yes but im wondering what else it could be

    #238280
    S1MON
    Participant

    ended up being a duff board all sorted now

Viewing 4 posts - 1 through 4 (of 4 total)