smeg wd16ba

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #33917
    robbo1973
    Participant

    been here today cust set on wash and it overfilled. now no matter where you put dial inc stop position it fills. i am thinking timer but at £145.79 retail i dont want to mis-diagnose.anybody had this fault before?

    cheers chris.

    #240569
    Jonah
    Participant

    Re: smeg wd16ba

    It will be the air tube from the front tub panel blocked, you will have to take the front off to get at it, not easy job mate !

    Dave

    #240570
    robbo1973
    Participant

    Re: smeg wd16ba

    thanks for reply when you say the air tube do you mean the pressure switch tube.i took the lid off and blow down it is clear. but surely set to stop the machine should be dead?

    cheers chris

    #240571
    Penguin45
    Participant

    Re: smeg wd16ba

    More likely a failed triac on the power board……..

    Chris.

    #240572
    robbo1973
    Participant

    Re: smeg wd16ba

    i priced timer up and by picture and description it comes with power board part no smg691650367. is this correct or i am being a bit slow seems odd to supply timer and sep board.

    cheers chris.

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.