Re: Fisher & Paykel GW611 New Fault
37 is the pump block error – drain not detected in the time allowed. This can be caused by a number of things, most of which you should be able to deal with yourself.
Firstly, kinked or trapped drain hose reducing flow. The pump can be blocked by debris or lost clothing. The cover above the pump can work loose, causing a loss of pump pressure. The pump itself may be failing – running for a while and then shutting down. If you can’t hear the pump running at all, there may be wiring problems or even a problem with the motor controller.
If it actually emptying, it is possible that the level switch is not detecting it due to water in the tube leading to it.
The pump haas a live supply to it at all times if the machine is plugged in, so power off before touching anything.
Penguin45.