Smeg DWI612C pumping when finished.

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Smeg DWI612C pumping when finished.

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #34154
    simtoms
    Participant

    Looking at a Smeg DWI612C int. D/W. Seems to wash fine and finish cycle but pump runs (continuously I think) at the end of a cycle. No leaks in base. Replacing slightly damaged door seal, but unrelated to fault probably. Anyone with some kind suggestions?! Many thanks, Simon.

    #241472
    simtoms
    Participant

    Re: Smeg DWI612C pumping when finished.

    Adding some extra details… the pump runs in pulses (ie on for a sec, off for two, on for a sec. etc.) and bleeps as it pumps. Unable now to reset prog. Just locked on this intermittent pumping. No flashing LEDs to indicate a fault. (5 LEDs and a prog. select button.) Thanks in anticipation.. 😉

    #241473
    eastlmark
    Moderator

    Re: Smeg DWI612C pumping when finished.

    soap dispenser mate! slave on any old solonoid valve to prove it. Of course you may have pulled a wire off the dispenser coil when doing the door seal…..

    #241474
    simtoms
    Participant

    Re: Smeg DWI612C pumping when finished.

    Thanks for that, I’ve heard of those solenoids doing strange things!
    Will check that out.

Viewing 4 posts - 1 through 4 (of 4 total)