Hotpoint WMA 30P ser no.82174792

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint WMA 30P ser no.82174792

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #34580
    robbra
    Participant

    Had to change door interlock but after this machine fills but no motor action. Brushes,taco all ok. On setting to any spin pump operates for couple of seconds then door lock light flashes fast stops then clicking from the pcb and door light flashes intermittantly.
    Using the last fault test proceedure in the fault code book it indicates just door lock.
    Any ideas please?
    Thanks.
    Rob

    #243220
    Martin
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    robbra wrote:Any ideas please?

    Module stuffed, but before you plug a new one in be sure that Interlock is changed AND that you look at the motor leads by the concrete weight. 😉

    #243221
    robbra
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    Thanks Martin.
    Did the lock but never checked the cables.
    Rob

    #243222
    smart
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    I AGREE WITH ROBBRA. HAVE HAD A FEW WHERE WIRES HAVE RUBBED AGAINST THE CONCRETE AND BLOWN THE INTERLOCK AND SOME TRACKS ON THE P.C.B WHICH WAS EASILY REPAIRED WITH A LINK WIRE

    #243223
    robbra
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    Hi Smart.
    You are wrong, Martin is the clever one, robbra (me) is the thicko.
    Rob

    #243224
    smart
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    sorry new to the forums 😳

    #243225
    robbra
    Participant

    Re: Hotpoint WMA 30P ser no.82174792

    Welcome Smart and enjoy it on here.
    You’ll see a lot of Martin, he’s a sort of father figure and pops up a lot on here
    Rob

Viewing 7 posts - 1 through 7 (of 7 total)