Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › CREDA T/D TVR 2
- This topic has 10 replies, 4 voices, and was last updated 18 years, 1 month ago by
richardable.
-
AuthorPosts
-
February 19, 2008 at 9:35 am #34693
richardable
Participanthad this from custome who had tried to fit new belt..fitted belt, turned on and off it whent. paused to reverse and stopped. motor buzzing…changed capacitor, no motor action…suggestions please.
richardFebruary 19, 2008 at 10:53 am #243633iadom
ModeratorRe: CREDA T/D TVR 2
Is the motor still buzzing after changing the capacitor?
Try it with the belt off, has the rear bearing collapsed?
Belt should be the later 9 rib 1703666.
Jim.
February 19, 2008 at 11:02 am #243634richardable
ParticipantRe: CREDA T/D TVR 2
jim. motor still buzzing after cap changed, bearing if fine, belt is correct one. thanks for reply
richardFebruary 19, 2008 at 5:09 pm #243635wilf
ParticipantRe: CREDA T/D TVR 2
if the customer has had a go at it I should check the wiring
wilf
February 19, 2008 at 6:41 pm #243636richardable
ParticipantRe: CREDA T/D TVR 2
can anyone send a wiring diagram for this t/d, especially the timer wiring.
thanks
richardFebruary 19, 2008 at 7:10 pm #243637lerch
ParticipantRe: CREDA T/D TVR 2
Have you checked the large relay at the front ???
part number 1702923 🙂
February 19, 2008 at 7:38 pm #243638richardable
ParticipantRe: CREDA T/D TVR 2
relay not checked, will do tomorrow.
richardFebruary 19, 2008 at 7:42 pm #243639iadom
ModeratorRe: CREDA T/D TVR 2
Old style, box relay for this is listed as 1701624. New PCB type relay is 1703617.
Would the motor hum if the relay was faulty, usually cuts out altogether?
Timer is the same as VTD00. Will try to dig out wiring for that one, might have to wait until after the footie though. 😉
Do you have the date code Richard?
Jim.
February 22, 2008 at 8:02 pm #243640iadom
ModeratorRe: CREDA T/D TVR 2
How did you go on with this one Richard, just curious. 😉
Jim.
February 22, 2008 at 8:17 pm #243641richardable
ParticipantRe: CREDA T/D TVR 2
jim, no real progress on this yet,,, time is the old enemy, however my engineer nathan confesses, under torture that he MAY have made a SMALL error when he rewired the door “interlock” three wires but there is no info on wiring diags i’ve been sent of a 3 terminal “interlock” ..have you got one?
thanks for your support
richard
richaFebruary 22, 2008 at 8:30 pm #243642lerch
ParticipantRe: CREDA T/D TVR 2
if you look at the door lock on the floor so spring on left and catch on right then from right to left :- red + white — brown(think it is anyway, other two are correct) — grey.
hope this helps. 😀
-
AuthorPosts
- You must be logged in to reply to this topic.