Hotpoint cond dryer timer

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #35103
    Madmac
    Participant

    Mod is TDC 30S. Allowed myself 15 mins to pop the usual pair of stats on today. Stats were fine tho. Front stat had a closed circ as well as did heater 😯 Do the heater contacts in timer fail on these machines does anyone know? Dont want to go buying timers willy nilly..

    #245157
    hotpnt
    Participant

    Re: Hotpoint cond dryer timer

    no, they used to a few years ago though, you should be able to check that you have voltage out of the timer to the stats/heater to confirm though, also make sure its not stuck in reverse (no heat on)

    #245158
    Madmac
    Participant

    Re: Hotpoint cond dryer timer

    Cheers for reply. Definately no volts to stats/heater, sorry should have said that. possibly is stuck in reverse tumble, never thought to check,was short on time. That being the case i guess its new timer anyway?? or can i hit it with a hammer.. id like that..

    #245159
    hotpnt
    Participant

    Re: Hotpoint cond dryer timer

    only other thing could be the float switch? that cuts the heater supply too