Re: Diplomat ADP8242 not playing!
Yup it’s a Smeg built for MFI – it sounds like it’s in the wrong mode and needs to be reset. The Smeg version has a flow meter which the Diplomat doesn’t but they both use the same board, just programmed differently. It sounds like the board is trying to find the flow meter and failing so is cancelling the program.
NWAR wrote:Sounds like the PCB needs to be reset:
With the door open switch the machine on using the door power button.
Press the program button 4 times within the first 3 seconds of the machine powering up.
At this point you should have both the first and last lights flashing and the middle three should be off – if not start over until you get this sequence.
Once you get the two outside lights flashing press the program button one more time and you will now be left with just one of the lights flashing.
Switch off the machine using the door power button but do not close the door.
Wait a few seconds (10-15 is plenty) then switch the machine back on and set it to a program to test.
Hopefully that should do the trick.
Give that a try before changing anything. Sometimes a power surge can cause the board to default to factory settings, often if it’s been left on overnight.