F&P Smartdrive 708 7.5 Error code 41 Home › Forums › Public Support Forums › International Forums › Australasian Appliance Forum › F&P Smartdrive 708 7.5 Error code 41 This topic has 1 reply, 2 voices, and was last updated 18 years ago by tobor. Viewing 2 posts - 1 through 2 (of 2 total) Author Posts March 17, 2008 at 7:44 am #35344 toborParticipant Hi Have a F&P gw708 which has error code 41 What does it mean? March 17, 2008 at 10:10 pm #246166 Penguin45Participant Re: F&P Smartdrive 708 7.5 Error code 41 Thermistor (temperature sensor) problem – readings are out of range. On yours it’s integral with the motor controller board, so is not servicable. New board is the solution………. Penguin45. Author Posts Viewing 2 posts - 1 through 2 (of 2 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In