Ariston A1535

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #35355
    Lawrence
    Participant

    No discernible fault codes ,m/c fils stops filling ,the fils agian ,stops filing and so on until it flods .
    Pressure chamber clear,presure switch clicks and checks through .
    any ideas ?
    Lawrence

    #246198
    iadom
    Moderator

    Re: Ariston A1535

    If pressure switch was operating correctly then at some point it should trigger the overfill part of the switch and knock the pump on. If it doesn’t then it suggests a fault in the pressure switch or pressure hose area, in theory anyway . 😉

    Jim.